Elevate your cooling experience with the leading VRF AC supplier in Bangladesh. We pride ourselves on delivering state-of-the-art Variable Refrigerant Flow systems tailored to meet the dynamic demands of modern living and working spaces. Our commitment to quality ensures that you receive not just air conditioning units, but innovative solutions designed for maximum efficiency and comfort. Partner with us for a seamless blend of cutting-edge technology and unmatched service. Transform your surroundings with our premium VRF AC offerings – your gateway to a cooler, smarter future in Bangladesh.
S.L | Description | Unit | Price(tk) |
---|---|---|---|
01 | Indoor Unit Fitting Charges (1 Ton to 5 Ton) | 01 Pcs | 1,500/- |
02 | Outdoor Base & Rubber Pad Fitting (Outdoor Loading & Unloading for Company) | 01 Pcs | 2,000/- |
03 | Y Joint (Refnet) Fitting | 01 Pcs | 500/- |
04 | Wire Remote Fitting | 01 Pcs | 150/- |
05 | Suction Copper Pipe Installation (Gas welding, Blazing Rod, AC Tiling Gas, Oxygen Gas, Nitrogen Gas, Nitrogen wash, Nitrogen Pressure with lick test) | 01 Rft | 100/- |
06 | Discharge Copper Pipe Installation (Gas welding, Blazing Rod, AC Tiling Gas, Oxygen Gas, Nitrogen Gas, Nitrogen wash, Nitrogen Pressure with lick test) | 01 Rft | 90/- |
07 | Power Line Collection Indoor Unit | 01 Pcs | 150/- |
08 | Power Line Collection Outdoor Unit | 01 Pcs | 1,000/- |
09 | Communication Cable | 01 Rft | 15/- |
10 | Drain Pipe Installation | 01 Rft | 15/- |
11 | Drain Pipe Conceal Installation | 01 Rft | 150/- |
12 | Glass Hole Installation | 01 Rft | 20/- |
13 | Fuel Tape Installation | 01 Rft | 15/- |
14 | Vacuum | 01 Unit | 3,000/- |
15 | Commissioning Charge | 01 Unit | 4,000/- |
S.L | Description | Unit | Price(tk) |
---|---|---|---|
01 | Indoor Unit Fitting Charges (1 Ton to 5 Ton) | 01 Pcs | 1,800/- |
02 | Outdoor Base & Rubber Pad Fitting (Outdoor Loading & Unloading for Company) | 01 Pcs | 2,200/- |
03 | Y Joint (Refnet) Fitting | 01 Pcs | 600/- |
04 | Wire Remote Fitting | 01 Pcs | 170/- |
05 | Suction Copper Pipe Installation (Gas welding, Blazing Rod, AC Tiling Gas, Oxygen Gas, Nitrogen Gas, Nitrogen wash, Nitrogen Pressure with lick test) | 01 Rft | 120/- |
06 | Discharge Copper Pipe Installation (Gas welding, Blazing Rod, AC Tiling Gas, Oxygen Gas, Nitrogen Gas, Nitrogen wash, Nitrogen Pressure with lick test) | 01 Rft | 110/- |
07 | Power Line Collection Indoor Unit | 01 Pcs | 180/- |
08 | Power Line Collection Outdoor Unit | 01 Pcs | 1,200/- |
09 | Communication Cable | 01 Rft | 17/- |
10 | Drain Pipe Installation | 01 Rft | 17/- |
11 | Drain Pipe Conceal Installation | 01 Rft | 170/- |
12 | Glass Hole Installation | 01 Rft | 22/- |
13 | Fuel Tape Installation | 01 Rft | 17/- |
14 | Vacuum | 01 Unit | 3,500/- |
15 | Commissioning Charge | 01 Unit | 4,500/- |
S.L | Description | Unit | Price(tk) |
---|---|---|---|
01 | VRF AC Installation (Package) | 01 Ton | 2,500/- |
S.L | Description | Unit | Price(tk) |
---|---|---|---|
01 | VRF AC Installation (Package) | 01 Ton | 3,200/- |
01. Above mentioned rate/quotations will be applicable for only the area of Dhaka city without VAT&TAX.
S.L | Description | Unit | Price(tk) |
---|---|---|---|
01 | Servicing per Indoor Unit (1 ton to 5 ton) | 01 Pcs | 1,500/- |
02 | Servicing per Outdoor Unit | 01 Pcs | 2,500/- |
03 | Overhauling Servicing per Indoor Unit (1 ton to 5 ton) | 01 Pcs | 2,500/- |
S.L | Description | Unit | Price(tk) |
---|---|---|---|
01 | Servicing per Indoor Unit (1 ton to 5 ton) | 01 Pcs | 2,500/- |
02 | Servicing per Outdoor Unit | 01 Pcs | 3,000/- |
03 | Overhauling Servicing per Indoor Unit (1 ton to 5 ton) | 01 Pcs | 3,000/- |
1. If you need an extra copper pipe after 10 feet of copper pipe, then the customer is required to pay an additional 350tk (three hundred and fifty) taka fer running feet copper pipe.
2. This Price is without VAT & TAX.
S.L | Description | Unit | Price(tk) |
---|---|---|---|
01 | Lick Repair | 01 Unit | 10,000/- |
02 | Vacuum & Gas Charge | 01 Unit | 15,000/- |
03 | Indoor Unit PCB Board Change | 01 Pcs | 10,000/- |
04 | Outdoor Unit PCB Board Change | 01 Pcs | 15,000/- |
05 | Indoor Unit & Outdoor Unit Fan Motor Open & Installation | 01 Pcs | 10,000/- |
06 | Commissioning Charge Per Project(Maximum 100 ton) | 01 Project | 15,000/- |
07 | Minimum Service Charge (Machine Checking) | 01 Unit | 8,000/- |
S.L | Description | Unit | Price(tk) |
---|---|---|---|
01 | Lick Repair | 01 Unit | 20,000/- |
02 | Vacuum & Gas Charge | 01 Unit | 20,000/- |
03 | Indoor Unit PCB Board Change | 01 Pcs | 20,000/- |
04 | Outdoor Unit PCB Board Change | 01 Pcs | 25,000/- |
05 | Indoor Unit & Outdoor Unit Fan Motor Open & Installation | 01 Pcs | 20,000/- |
06 | Commissioning Charge Per Project(Maximum 100 ton) | 01 Project | 25,000/- |
07 | Minimum Service Charge (Machine Checking) | 01 Unit | 20,000/- |
1. If you need an extra copper pipe after 10 feet of copper pipe, then the customer is required to pay an additional 350tk (three hundred and fifty) taka fer running feet copper pipe.
2. This Price is without VAT & TAX.
A Variable Refrigerant Flow (VRF) system is an advanced and energy-efficient HVAC solution that provides precise control over temperature regulation in commercial and residential spaces. Unlike traditional air conditioning systems, VRF systems use a variable-speed compressor to adjust the flow of refrigerant to different indoor units, enabling simultaneous heating and cooling in various zones.
A VRF system operates by connecting a single outdoor unit to multiple indoor units within a building. The outdoor unit contains a variable-speed compressor that modulates the flow of refrigerant based on the specific cooling or heating needs of each indoor unit. This dynamic control allows for the creation of different climate zones, optimizing comfort and energy consumption.
Ensuring the longevity and efficiency of a VRF AC system in Bangladesh involves regular and thorough maintenance. Here are key steps:
Note: For More Information Visit Our Other Website Ponnomela.com
© 2006-2025 acservicebd.com | All Rights Reserved |